§Ó©|»ö¾¹ªÑ¥÷¦³­­¤½¥q

¢xµn¤J µù¥U ¢x¼t°Ó±M°Ï¢x¶i¾n¥Ó½Ð¢x¼s§i¥Zµn¢x§¹¦¨­qÁʸ߻ù¢x

¦WºÙ ÂùÆN¥ø·~¦³­­¤½¥q¡eÂ÷¤ß¾÷ / ²GºA´á®e¾¹¡f

¦W¿ý¡B°Ó«~

±ÄÁÊ«ü«n

¼t°Ó«ü«n

¼t°Ó¦W¿ý

¤Wºô¼t°Ó

¼t°Ó°ÊºA

¯S´f°Ó«~

³Ì·s°Ó«~

³Ì·s¼t°Ó

¼ö½æ°Ó«~

³Ì·s¦W¿ý

ÂI¾\±Æ¦æ

¬¡°Ê°T®§

½u¤W¸ß»ù

¤@°_°Q½×°Ï

¤Æ¤u¦r¨å

»ö¾¹¦Ê¬ì

¯Ó§÷¦Ê¬ì

°ò¦]¬ì¾Ç

ºÞ¬W¤ÀªR

²£·~°ÊºA

¼Ö¬¡¾i¥Í

¤¤ÂåÃĨå

¯e¯fÂåÅQ

®iÄý°T®§

®É¨Æ³ø¾É

¥ø·~µJÂI

¼tµP¬G¨Æ

¸ÜÃD¼t°Ó

¸ÜÃD°Ó«~

Tw17!ªA°È

¼s§i¥Ó½Ð

¥»¤éÀu´f

¼t°Ó¥Ó½Ð

¥ø·~ºô¯¸

»ö¾¹±ÄÁÊ«ü«n¥Ó½Ð

»ö¾¹¥ø·~ª©¡ãºô¯¸½d¨Ò
»ö¾¹±ÄÁÊ«ü«n--¤£­­°Ó«~µ§¼Æ¥ô§A©ñ

¤j¥x¥_¦yºÝ»ö¾¹¦³­­¤½¥q

²£«~¸Ô²Ó¸ê®Æ
TSL¯S®í«¬¤j¶b½ü±i¤O¶Ç·P¾¹

¤H®ð«ü¼Æ

9590
TSL
¯S®í«¬¤j¶b½ü±i¤O¶Ç·P¾¹
electronic tension sensors for measuring sensitive materials
¼tµP¡G¥N²z
¨ÑÀ³°Ó¡G¤j¥x¥_¦yºÝ»ö¾¹¦³­­¤½¥q
©w»ù¡G»P§Ú­ÌÁpµ¸
²£«~³W®æ¤Î¯S¦â
¤¤¤å»¡©ú

 

SPEC.
 tension ranges from 0 - 50 cN up to 0 - 1000 cN
Stationary electronic tension sensors  for measuring sensitive materials as optical fibres, carbon fibres, technical fibres etc.
Large, smooth running guide rollers for minimized material deflection with 32 mm groove O

Tension meter is available with digital output for data processing with PC

Special Features

  • Large bending radius for gentle handling of sensitive material
  • Tension sensor with integrated measuring amplifier
  • Smooth running, V-grooved guide rollers, ball-bearing mounted
  • Best suitable for low tension ranges
  • Various output signals
    - analog
    - digital (optional)
    - current (optional)
  • Easy calibration to customized material by operator
  • Tension sensor with mechanical overload protection

Standard Features 

  • Tension sensor with rugged aluminium housing
  • Certificate of Compliance with the order 2.1 according EN 10204 is included
  • Optionally available: Inspection Certificate 3.1 according EN 10204 with calibration report

Available Models

Model Tension Range
cN
Measuring Head Width*
mm
SCHMIDT
Calibration Material**

TSL-50

0 - 50

150

PA: 0.12 mm O
TSL-100

0 - 100

150

PA: 0.12 mm O
TSL-200

0 - 200

150

PA: 0.12 mm O
TSL-500

0 - 500

150

PA: 0.20 mm O
TSL-1000

0 - 1000

150

PA: 0.30 mm O

Specifications 

Calibration: According to SCHMIDT factory procedure
Accuracy: ¡Ó1 % full scale and ¡Ó1 digit
other calibration materials:
¡Ó3 % full scale or better
Overload protection: 100 % of tension range
Measuring principle: Strain gauge bridge
Measuring roller deflection: Max. 0.5 mm
Natural frequency: Approx. 500 Hz, depending on tension range
Signal processing: Analog (option: digital)
Temperature drift: Less than ¡Ó0.05 % full scale/oC
Output Signal: Standard: 0 - 1 V DC (analog) impedance: Æà 5 kΩ
Option: 0 - 10 V DC (analog), or 4 -20 mA (current)
digital RS 232
Damping (fg): Standard: 30 Hz (other values on request)
Temperature range: 10 - 45 oC
Air humidity: 85 % RH, max.
Power supply: +12 ... 24 V DC, max. 50 mA regulated
Housing material: Aluminium
Weight, net (gross): Approx. 360 g (approx. 500 g)
NOTES.
¦PÃþ°Ó«~ >>
¡¹ DX2-2000-EDM/3000/4000¡@±i¤O­p(½u¤Á³Î¾÷¥Î) DX2-2000-EDM To DX2-4000EDM¡@Tension Meter for EDM Model: DX2-2000-EDM / DX2-3000-EDM /DX2-4000-EDM
¡¹ DN1-120 To DN1-50K-L¡@¯¼Â´½uÆl±i¤O­pDN1-120 To DN1-50K-L¡@Tension Meters Model:DN1-120 To DN1-50K-L
¡¹ DX2-50 To DX2-20K-L¡@±i¤O´ú©w¾¹(¿ö°w¦¡) DX2-50 To DX2-20K-L¡@Tension Meters Hand-Held Mechanical Model: DX2-50 T0 DX2-20K-L
¡¹ DXR-2000 To DXR-50K-L¡@Ÿõ½ü¦¡±i¤O­pDXR-2000 To DXR-50K-L¡@Tension Meters Model: DXR-2000 To DXR-50K-L
¡¹ DTBB-200 To DTBB-50K-L¡@±i¤O­p(¼Æ¦r«¬) DTBB-200 To DTBB-50K-L¡@Tension Meters Hand-Held Electronic Model: DTBB-200 To DTBB-50K-L
¡¹ DXK-300 / 1000 / 2000¡@¸g¯½±i¤O´ú©w¾¹(«ü°w¦¡) DXK-300/1000/2000¡@Yarn Tension Meters Model:DXK-300,DXK-1000,DXK-2000
¡¹ DXT-50 To DXT-20K-L¡@½¦±aª¬±i¤O­p(«ü°w¦¡) DXT-50 To DXT-20K-L¡@TENSION METERS. Model: DXT-50 To DXT-20K-L
¡¹ DXF-120/200/400/1000¡@¥úÅÖºÒÅÖ±i¤O´ú©w¾¹(«ü°w¦¡) No. DXF-120/200/400/1000¡@Optical, Carbon Fibers Tension Meters Model: DXF-120 To DXF-1000
¡¹ DXL-2000 / 5000 / 10K¡@¥úÅÖ±i¤O´ú©w¾¹(«ü°w¦¡) DXL-2000/5000/10K¡@Optical Fibers Tension Meters Model:DXL-2000 / 5000 / 10K
¡¹ DXP-50 / 120 / 200¡@±i¤O´ú©w¾¹(«ü°w¦¡) Model:DXP-50/120/200¡@Tension Meters Model: DXP-50,DXP-120,DXP-200
¡¹ DXB-50 To DXB-20K-L¡@±i¤O´ú©w¾¹(«ü°w¦¡) DXB-50 To DXB-20K-L¡@Tension Meters Model: DXB-50 To DXB-20K-L
¡¹ DXE-50 To DXE-2000¡@±i¤O´ú©w¾¹(«ü°w¦¡) DXE-50 To DXE-2000¡@Tension Meters Model: DXE-50/120/200/400/1000/2000
¡¹ DXV-50 To DXV-2000¡@±i¤O´ú©w¾¹(«ü°w¦¡) DXV-50 To DXV-2000¡@Tension Meters Model: DXV-50 To DXV-2000
¡@
¡@
 
¡õ¡iTSL¡B¯S®í«¬¤j¶b½ü±i¤O¶Ç·P¾¹¡B¤j¥x¥_¦yºÝ»ö¾¹¦³­­¤½¥q¡B¥N²z¡j¬ÛÃöªº°Q½×¥DÃD¡õ
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88

¡£¦^²£«~¥D¤ÀÃþ¡¤¡£§¹¦¨­qÁʸ߻ù¡¤

Bookmark and Share






»ö¾¹±ÄÁÊ«ü«n--¤£­­°Ó«~µ§¼Æ¥ô§A©ñ
¥¼¨ÓªA°È¤u·~ Á`¥N²z ¤é¥»©¥¥ÐµLªo¦¡ªÅÀ£¾÷
©¥¥Ð±À¥X¥@¬É³ÌÀR­µ41dBµLªo´õ¨÷¦¡ªÅÀ£¾÷
¥@¬É²Ä1¥xµLªo´õ¨÷ªÅÀ£¾÷(µLªo°ê»Ú»{ÃÒ-¹êÅç«Ç)
¥»¤½¥q±N©ó2022/09/14-2022/09/16°Ñ®iSEMICON TAIWAN 2022 («n´ä®iÄýÀ]1¼Ó I3008Åu¦ì)
¤é¥»MECC¤½¥q³Ì·s±À¥X"¤â«ù¦¡¹q¯¼³]³Æ"¡A¥iÀ³¥Î©ó¥ÍÂå¡B¤Æ§©«~¤Î±Ð¾Ç¬ã¨sµ¥¥Î³~¡C

>>§ó¦h

Åã·LÃèªo (°ª­¿Åã·LÃè°ò¥»«¬)
°ê»Ú»{ÃÒµLªo´õ¨÷¦¡ªÅÀ£¾÷ (2HP)
¹êÅç«ÇÀ³¥Î°®¦¡µLªo´õ¨÷¦¡¯uªÅÀ°®ú
¦çªA?¥~Àô¹Ò´ú©w?¸m PTH-2
¤HÅé¼ö¯à¸ÕÅç¾÷ (¤HÊ^§Ö¾A©Ê «O·Å©Ê¸ÕÅç¾÷) ITM-ST/ITM-SD
BAKER¦¡¶î½¤¾¹ / ¥i½Õ¦¡ No.1510
ºôª©±i¤O­p(¼Æ¦r¦¡)
IHARA ¤À¥ú¦â®t­p / ¿@«×­p S300
IHARA AccuDot ¥b¦â½ÕºôÂI´ú¶q»ö
UNITTA U-508 /U-550 ­µªi¥Ö±a±i¤O­p
ABD- 100 ¯»Åé¯S©Ê´ú©w¾¹ ¦w®§¨¤/°²¤ñ­«/¤À´²«×
PM-9002HV °ª°Å¤Á¤O±ÛÂàÂH«×­p

>>§ó¦h



¯S´f°Ó«~come soon


¥xÆW»ö¾¹ºô±M¬°»ö¾¹¶}ÅPºô¸ô°Ó¾÷--»ö¾¹±ÄÁÊ«ü«n
»ö¾¹¥ø·~ª©¡ãºô¯¸½d¨Ò
§Ó©|»ö¾¹ªÑ¥÷¦³­­¤½¥q

¤O©ú»ö¾¹¦³­­¤½¥q

¤j¥x¥_¦yºÝ»ö¾¹¦³­­¤½¥q

»Å·R®a±Ú!www.coi.tw¡@¡@¡@¡@
¢xTw17®a±Ú¢x¥I´Ú¤è¦¡¢x¥Ó½Ð¶i¾n¢x¼s§i¥Zµn¢x
 Copyright © 2006-2010 tw17 All rights reserved.